UL/ULC Fire Detection and Alarm System
FW2105 UL Intelligent Fire Alarm Control Panel
FW2105 UL Intelligent Fire Alarm Control Panel
DESCRIPTIONS
The FW2105 is an intelligent Fire Alarm Control Panel (FACP) designed for small to medium-scale facilities. The FW2105 is ideally suited for both new and retrofit commercial, institutional, and industrial fire detection and notification applications. The FW2105 is a state-of-art addressable fire control system that meets the requirements of UL 864, and CAN/ULC-S527. It can support up to 9 Signaling Line Circuits and 2268 addressable devices/points, 12 Notification Appliance Circuits and 4 form C dry relay contacts. The panel has a 7” color LCD and a resolution of 800×480 pixels screen, 6 auxiliary function keys and 12 LED indicators making it a highly intuitive fire alarm user interface.
The FW2105 can connect with up to 32 remote annunciators via an ANU to form a fire emergency detection and notification network system.
KEY FEATURES
- Up to 9 Signaling Line Circuits and 2268 addressable devices/points
- Up to 12 Notification Appliance Circuits
- 4 form C dry relay contacts
- 8 Isolated SLC circuits
- A 7” color LCD with 800×480 resolution
- 12 LED indicators , 6 auxiliary function keys
- 1000+5000 events historical log
- Single-phase earth fault detection
- Manual alarm function
- PAS (Positive Alarm Sequence) function
- Two-Stage alarm function
- Silent inhabit function, 0~20 min available.
- Trouble/Supervisory Resound
FW2121 UL Remote LCD Annunciator
FW2121 UL Remote LCD Annunciator
DESCRIPTIONS
The FW2121 fire display panel is used to repeatedly display the fire alarm information on the floor or independent fire prevention area. The FW2121 is installed in the floor or the independent fire prevention area, which can receive the fire alarm information of the loop, across the loop and across the machine and make the corresponding alarm prompt.
KEY FEATURES
- Intelligent remote LCD annunciator
- Class A and Class B circuits available
- LCD display with 320×80 resolutions
- Fully icon indications and intuitive fire alarm
- Display annunciate up to 8 zones simultaneously
FW2129 UL Remote LED Annunciator
FW2129 UL Remote LED Annunciator
DESCRIPTIONS
The Led Annunciator are used to display zone events which are from FACP FW2105 /FW2107. LED Annunciator include two types: Local Annunciator FW2261 and Remote Annunciator FW2129.
KEY FEATURES
- 4 options:1 bay,2 bay,3 bay and 5 bay
- 4 button functions
- 8 slots per bay, 8 modules
FW2511 UL Addressable Smoke Detector
FW2511 UL Addressable Smoke Detector
DESCRIPTIONS
The FW2511 is an intelligent Smoke Detector. It’s certified with UL 268, 7th edition and ULC-S529 which passes flaming and smoldering polyurethane tests, as well as the Cooking Nuisance test. The Maple Armor’s new detection technology helps to reduce nuisance alarms and improve reliability of fire detection.
KEY FEATURES
- Photo Electric smoke detector with dual light source
- Embedded Microcontroller Unit for self-diagnostic tests and result analysis
- Two Led lights allow for 360° viewing
- 3-level alarm sensitivity
- 3 base options, FW2501 (4’’), FW2502(6’’), FW2509 (sounder base)
FW511 UL/FM Addressable Smoke Detector
FW511 UL/FM Addressable Smoke Detector
DESCRIPTIONS
KEY FEATURES
FW2521 UL Addressable Heat Detector
FW2521 UL Addressable Heat Detector
DESCRIPTIONS
The FW2521 is an intelligent Heat Detector for indoor use with both fixed-temperature alarm and rate-of-rise alarm characters. It features a slim design, which combines visual appeal with a high standard of reliability. The detector has a Microcontroller Unit (MCU) performing comprehensive
Self-diagnostic tests, and result analysis.
KEY FEATURES
- Combined heat detection: Fixed / Rate-of-Rise (ROR)
- Embedded Microcontroller Unit for self-diagnostic tests and result analysis
- Two Led lights allow for 360° viewing
- IP33 rating, with the optimal performance under condensation when using together with MA-BWA-S.
FW521 UL/FM Addressable Heat Detector
FW521 UL/FM Addressable Heat Detector
DESCRIPTIONS
KEY FEATURES
FW2509 UL Sounder Base
FW2509 UL Sounder Base
DESCRIPTIONS
The FW2509 is designed for use with Maple Armor detector heads or equivalent and is intended to provide occupant notification in fire events within the protected space. It meets the needs of dwelling unit applications. The FW2509 can produce multiple tone patterns including temporal 3, temporal 4, continuous, 20bpm, 60bpm and 120 bpm required by NFPA 72 for commercial and residential applications. 7 levels of sound outputs are selectable. The FW2509 can be commanded by the Fire Alarm Control Panel. The panel can command an individual FW2509, or a group of FW2509 by pre-programming. FW2509 does not take address on SLC.
KEY FEATURES
FW272X Series UL Intelligent Manual Pull Station
FW272X Series UL Intelligent Manual Pull Station
DESCRIPTIONS
FW2721 Dual Action, Single Stage Addressable Manual Pull Station
FW2722 Two Stage Addressable Manual Pull Station
FW2723 Single Action, Single Stage Addressable Manual Pull Station
The FW272X series addressable Manual Pull Stations are UL listed devices according to UL 38 and ULC-S528 for Fire Protective Signaling Systems for indoor use. They made from durable materials and solid parts for long lasting performance.
The 272X series occupy a single address on the ALU and transmit alarm event status to the panel when activated. The 272X series contain dry contact with normally open or normally close options available.
KEY FEATURES
- Dual action station
- Addressable
- PUSH HERE and PULL DOWN
- Status LED Indicator
- Easy to use reset key
- Included dry contact (2A, 24VDC)
- Two Dry contact options (N/O or N/C)
FW2961 UL Addressable / Conventional Horn Strobe
FW2961 UL Addressable/ Conventional Horn Strobe
DESCRIPTIONS
KEY FEATURES
FW2971 UL Addressable / Conventional Horn
FW2971 UL Addressable/ Conventional Horn
DESCRIPTIONS
KEY FEATURES
FW29XX Series Addressable Horn Strobe
FW29XX Series Addressable Horn Strobe
DESCRIPTIONS
The FW2961 Horn Strobe, FW2971 Horn, and FW2981 Strobe are a family of visual and audible signal appliances with light sources generated from white LED, listed according to UL 1971, UL 1638, UL 464, ULC-S525 and ULC-S526 for indoor use.
These appliances can operate in both conventional and addressable modes, offering flexibility in system design and implementation. Six levels of light output, seven levels of sound outputs are selectable.
The appliance has the feature that can synchronize multiple horn and/or strobes based on loop.
KEY FEATURES
Horn features
- Conventional or addressable
- Seven levels of sound pressure settings
- Switchable buzzer tones
- Built-in synchronization
Strobe features
- Multi candela LED Strobe: 15,30,75,110,140,177 cd
- Six levels light intensity settings
- High-intensity LED light source
- Built-in synchronization
FW2811 UL Addressable Input Module
FW2811 UL Addressable Input Module
DESCRIPTIONS
The FW2811 input module monitors a single contact. The input line is monitored for open line faults and ground faults, and the contact must thus be wired with an end-of-line resistor. It is an intelligent addressable module and takes one address on SLC or Data Communication Link (DCL) of the fire alarm control panel.
The FW2811 is a UL listed device according to UL864 and ULC-S527 and the type of the input contact is configurable for 4 types:
- Alarm
- Supervisory
- Trouble
- Monitor or feedback
KEY FEATURES
FW2821 UL Addressable Input/Output Module
FW2821 UL Addressable Input/Output Module
DESCRIPTIONS
FW2821 is an intelligent input-output module for fire protective signaling systems for indoor use. The FW2821 is an intelligent addressable module and takes one address on the SLC or DCL of the FACP. The FW2821 offers a single 24VDC output and an input switch. It monitors for open line faults and ground faults on the input side, while on the output side, it keeps track of open line, short circuit, ground faults, and the loss of the external 24VDC power source. Input switch can be configurable for 4 types:
- Alarm
- Supervisory
- Trouble
- Monitor or feedback
KEY FEATURES
FW2831 UL Addressable Relay Module
FW2831 UL Addressable Relay Module
DESCRIPTIONS
The FW2831 relay module provides two control relay outputs, which will be activated simultaneously. When the outputs are activated, the device LED will indicate the event condition by red steady on. A return to normal condition will cause the event to disappear and the device LED indicator will return to red every 4 seconds.
- Intelligent addressable module
- Two control relay outputs
- LED indicator
- SLC/DCL Class A or Class B
KEY FEATURES
FW2841 UL Addressable Conventional Zone Module
FW2841 UL Addressable Conventional Zone Module
DESCRIPTIONS
The FW2841 conventional zone module is intended to allow Maple Armor intelligent fire alarm control panels to interface and monitor 2-wire conventional detectors in retrofit applications. The initiating zone can support a mix of 2-wire conventional automatic detectors as well as normally open dry contact alarm initiating devices.
- Conventional module
- Supports a zone of up to 32 conventional smoke detectors
- Compatible with Class B and Class A wiring
KEY FEATURES
FM Aspirating Smoke Detector
FW2601 FM PipeSense Aspirating Smoke Detector
FW2601 FM PipeSense Aspirating Smoke Detector
DESCRIPTIONS
The FW2601 series aspirating smoke detector offers abundant pipeline configurations. Each pipeline has an independent detection chamber to ensure reliable high-sensitivity detection.
The default pipe addressing function and independent PT platinum airflow sensor for each pipe enhance the accuracy of detection and alarm. The advanced laser detection technology features high sensitivity, a wide sensitivity range, and good consistency. The extra-long pipe and abundant holes along the pipe ensure extensive coverage and effective detection.
The FW2601 utilizes micro-dust separation technology with improved immunity to false alarms and longer filter lifespan. It can record up to 20,000 events and it’s easy to integrate and interface with other systems.
KEY FEATURES
- Available in 1/2/4 extra-long pipes
- Modular based design and modular based replacement
- Independent detection chamber for each pipe
- Default pipe addressing
- Independent airflow sensor for each pipe
- High sensitivity laser detection
- 4-level programmable alarm level
- Micro-dust separation technology
- Event log capacity up to 20,000
FW2601 FM Series
FW2601 FM Series
DESCRIPTIONS
The FW2601 series aspirating smoke detector offers abundant pipeline configurations. Each pipeline has an independent detection chamber to ensure reliable high-sensitivity detection.
The default pipe addressing function and independent PT platinum airflow sensor for each pipe enhance the accuracy of detection and alarm. The advanced laser detection technology features high sensitivity, a wide sensitivity range, and good consistency. The extra-long pipe and abundant holes along the pipe ensure extensive coverage and effective detection.
The FW2601 utilizes micro-dust separation technology with improved immunity to false alarms and longer filter lifespan. It can record up to 20,000 events and it’s easy to integrate and interface with other systems.
KEY FEATURES
- Available in 1/2/4 extra-long pipes
- Modular based design and modular based replacement
- Independent detection chamber for each pipe
- Default pipe addressing
- Independent airflow sensor for each pipe
- High sensitivity laser detection
- 4-level programmable alarm level
- Micro-dust separation technology
- Event log capacity up to 20,000
UL Voice Alarm and Fire Telephone system
FW151 UL Digital Voice Control Panel
FW151 UL Digital Voice Control Panel
DESCRIPTIONS
The digital voice control panel is an intelligent emergency voice evacuation system designed for small and medium-scale facilities. The FW151 digital voice control panel is ideally suited for both new and retrofit commercial, institutional, and industrial applications. The FW151 digital voice control panel is a digital communication system that meets the requirements of UL 864 in the 10th Edition and CAN/ULC-S527 in the 3rd edition.
KEY FEATURES
- 4.3” full color TFT LCD, Simple and easy to use operation interface
- Up to 128 zone selector buttons and 256 zone indicators per DCP making it a highly intuitive fire alarm user interface
- Indication of all required fault conditions
- Digitized voice capability
- Master microphone and telephone handset can be monitored by the master panel.
FW151-FP UL Digital Voice Control Panel
FW151-FP UL Digital Voice Control Panel
DESCRIPTIONS
FW151-FP is a modalized fire telephone control system, which contains the fire telephone related components from Maple Armor BlazeCom™series voice control system.
The master display unit contains full color 4.3” LCD, 8 LEDs for signal status, 8 LEDs for system status, 8 functional buttons, 24 buttons logical input keypad, 1 buzzer and 1 master microphone.
KEY FEATURES
- 4.3” full color TFT LCD, Simple and easy to use operation interface
- Up to 64 zone selector buttons and 128 zone indicators per DCP making it a highly intuitive fire alarm user interface
- Master microphone and telephone handset can be monitored by the master panel.
- Additional 4 conventional telephone wall jacks (FW864) can be connected to each addressable telephone wall jacks (FW864A) and are intended to be installed in the same zone.
UL/FM Addressable Fire Extinguishing System
FW2107 UL Fire Alarm Control Panel/Agent Releasing Panel
FW2107 UL Fire Alarm Control Panel/ Agent Releasing Panel
DESCRIPTIONS
FW2107 is an Intelligent Fire Alarm Control Panel (FACP) designed for small and medium-scale facilities. The FACP is ideally suited for both new and retrofit commercial, institutional, and industrial fire detection and notification applications. It is with dual hazard agent releasing that meets the requirements of UL 864, and CAN/ULC-S527.
The FACP supports up to 252 devices, 2 NACs and 3 Form-C relays (pre-programmed for Alarm, Trouble and Supervisory). In addition, the control panel can be used for hazard agent releasing application via the SLC loop.
KEY FEATURES
- 1 Signaling Line Circuits and 252 addressable devices/points
- Up to 2 Notification Appliance Circuits
- 3 form C dry relay contacts
- 16 built in annunciator zones
- Up to 2 releasing zone
- A 2.8” true color LCD
- Up to 16 zone LED annunciator
FW2731 UL Manual Release
FW2731 UL Manual Release
DESCRIPTIONS
The FW2731 Manual Release is designed for use with Fire Alarm Control Panel that include agent release capability. It’s for indoor use and is constructed using durable materials and solid components to ensure long-lasting performance.
KEY FEATURES
- Single action station
- Addressable
- Status LED Indicator
- Easy to use reset key
- Two Dry contact options (N/O or N/C)
FW2732 UL Abort Switch
FW2732 UL Abort Switch
DESCRIPTIONS
The FW2732 Abort Switch is designed for use with Fire Alarm Control Panel that include agent release capability. It is a single action Abort Switch. When the releasing zone FW2107 enters the alert or pre-discharge state, pressing and holding the abort switch will cancel the sequence for releasing the agent. The LED flashes once every 4 seconds in normal standby condition, and turn steady on when press.
KEY FEATURES
- Addressable single action
- Abort Switch
- Status LED Indicator
LPCB Addressable Fire and Alarm System
VI-6847 LPCB Intelligent Addressable Fire Alarm Control Panel
VI-6947 LPCB Intelligent Addressable Fire Alarm Control Panel
DESCRIPTIONS
- Addressable fire alarm control panel LPCB approved to EN 54-2 and EN 54-4
- 7-inch touch screen and touch-sensitive buttons is used for HMI and 18 LED for status indication
- Support Class A loop wiring mode and Class B star wiring mode
- Maximum 4 detection loops, each loop has 256 addressable devices in Class A mode or Switch to 512 addressable devices in Class B mode
- 36 Zone indication for Fire, Fault, Disable
- V-6847 has passed the optional requirement of EN54-4 that It can control FPE equipment, and detecting fault status from FPE.(Fire protection equipment such as: Water system, ventilation system, fire extinguish system etc.)
- 2 Programmable sounder output terminal for conventional sounder.
- 6 Programmable output for FPE device
- 24V/3AAuxiliary power supply output for remote device
- An additional NET card can enable networking through CANbus
- True peer-to-peer(P2P) networking, it can support up to 128 FACPs
- (V-6847) being interconnected
- It is possible to preview the status of the entire fire alarm system through any FACP within this network
KEY FEATURES
AC Main Power 3.0A@100~120VAC,50/60Hz
Standby Current ≤1.5Al Max.a En54-4
Alarm Current ≤2.5AI Max.b En54-4
Battery The enclosure of panel can accommodate two standard-sized 12V/7AH batteries connected in series
Temperature Range -10℃~50℃
Humidity ≤95%RH,(40±2℃)No condensat ion
Loop Default 1 loop with 512 points
Maximum 4 loop with 2048 points
Sounder Output 2 Programmable conventional sounder output. Rated @1 amp each
Pro I/O Output Needs VI-6159 Terminal box for Programmable Remote VO control
Alarm Output Relay 1A at 30VDC
Fault Output Relay 1A at 30VDC
Network CANbus, Baudrate
Dimension 480x355x120mm
VI-6627 LPCB Addressable Smoke Detector
VI-6627 LPCB Addressable Smoke Detector
FEATURES
- Addressable Smoke Detector
- Advanced embedded Micro Controller Unit (MCU)
- Drift compensation and dirty notification on fire alarm control panel
- One LED for 360◦ visibility
- Manual addressing via programmer
- 4 sensitivity levels designed for different application environments
- LPCB approved to EN54-7
TECHNICAL DATA
Operating Voltage: 16-28V (Modulated-pulse)
Standby Current: ≤0.5mA
Alarm Current: ≤1.0 mA
Wiring: Two-wire (non-polarized)
Temperature Range: -10°C ~ 50°C
Humidity: ≤95%RH, (40±2°C) No condensation
LED Alarm Indication: Red light emitting
LED Polling Indication: Red light flashing
Sensitivity Mode: 4
Installation Base VB-6617
VI-6637 LPCB Addressable Heat Detector
VI-6637 LPCB Addressable Heat Detector
FEATURES
- Addressable Heat Detector
- Advanced embedded Micro Controller Unit (MCU)
- Dual-response mode A1R/A2
- One LED for 360ᴼ visibility
- Manual addressing via programmer
- LPCB approved to EN54-5
TECHNICAL DATA
Operating Voltage: 16-28V (Modulated-pulse)
Standby Current: ≤0.5mA
Alarm Current: ≤1.0 mA
Wiring: Two-wire (non-polarized)
Temperature Range: -10°C ~ 50°C
Humidity: ≤95%RH, (40±2°C) No condensation
LED Alarm Indication: Red light emitting
LED Polling Indication: Red light flashing
Respond Mode: A1R/A2
IP Rating: IP32
Installation Base: VB-6617
VI-6647 LPCB Addressable Multi-Sensor Detector
VI-6647 LPCB Addressable Multi-Sensor Detector
FEATURES
- Addressable Multi-sensor Detector
- Advanced embedded Micro Controller Unit (MCU)
- Drift compensation and dirty notification on fire alarm control panel
- Dual-response mode A1R/A2
- Two LEDs for 360ᴼ
- Manual addressing via programmer
- LPCB approved to EN 54-5& EN 54-7
TECHNICAL DATA
Operating Voltage 16-28V (Modulated-pulse)
Standby Current ≤0.5mA
Alarm Current ≤1.0 mA
Wiring Two-wire (non-polarized)
Temperature Range -10°C ~ 50°C
Humidity ≤95%RH, (40±2°C) No condensation
LED Alarm Indication Red light emitting
LED Polling Indication Red light flashing
Respond Mode A1R/A2
IP Rating IP32
Installation Base VB-6617
VI-6657 LPCB Addressable Manual Call point
VI-6657 LPCB Addressable Manual Call point
FEATURES
- Addressable Manual Call Point
- Advance embedded Micro Controller Unit (MCU)
- The button ca be pressed in case of fire
- Reset by a special key
- LED Indication for operation status
- Manual Addressing via programmer
- Indoor use
- LPCB approved to EN 54-11
TECHNICAL DATA
Operating Voltage 16-28V (Modulated-pulse)
Standby Current ≤0.5mA
Alarm Current ≤1.0 mA
Wiring Two-wire (non-polarized)
Temperature Range -10°C ~ 50°C
Humidity ≤95%RH, (40±2°C) No condensation
LED Alarm Indication Red light emitting
LED Polling Indication Red light flashing
Call Point Type Type A-Direct operation
(single action and resettable)
Call Point Principle Operate by switch
IP Rating IP43
VI-6737 LPCB Addressable Sounder Beacon
VI-6737 LPCB Addressable Sounder Beacon
FEATURES
- Addressable Sounder Beacon
- Type A : Indoor use
- 4 Sounder output Levels
- 16 tones for notification
- Switchable Sounder/optical indication.
- High-luminance LED
- Manual addressing via programmer
- Activated directly by loop voltage without AUX 24VDC
- LPCB approved to EN 54-3
TECHNICAL DATA
Operating Voltage 16-28V (Modulated-pulse)
Standby Current ≤0.3mA
Alarm Current ≤8 mA
Wiring Two-wire (non-polarized)
Temperature Range -10°C ~ 50°C
Humidity ≤95%RH, (40±2°C) No condensation
LED Alarm Indication Red light emitting
LED Polling Indication Red light flashing
Tones 16
IP Rating IP43
Installation Base VB-6619
VI-6717 LPCB Addressable Monitor Interface
VI-6717 LPCB Addressable Monitor Interface
FEATURES
- Addressable Input Monitor Module
- Easy Installation
- Input circuit line detection with EOL resistor
- LPCB approved to EN 54-18:2005
TECHNICAL DATA
Operating Voltage 16-28V (Modulated-pulse)
Standby Current ≤0.5mA
Alarm Current ≤1.0 mA
Wiring Two-wire (non-polarized)
Temperature Range -10°C ~ 50°C
Humidity ≤95%RH, (40±2°C) No condensation
Operating Indication Operate LED Flashing
Signal Input Action LED Emitting
Fault Indication Operate LED Off
IP Rating IP32
Installation Base VB-6618
VI-6727 LPCB Addressable Control Interface
VI-6727 LPCB Addressable Control Interface
FEATURES
- Addressable Input and Output Module
- Easy Installation
- Output relay capacity: 30VDC/1A
- Input circuit line detection with EOL resistor
- LPCB approved to EN 54-18:2005
TECHNICAL DATA
Operating Voltage 16-28V (Modulated-pulse)
Standby Current ≤0.5mA
Alarm Current ≤1.0 mA
Wiring Two-wire (non-polarized)
Temperature Range -10°C ~ 50°C
Humidity ≤95%RH, (40±2°C) No condensation
Remote Control Output Indication Output LED Emitting
Signal Inputting Indication Input LED Emitting
IP Rating IP32
Installation Base VB-6618
VI-6777 LPCB Addressable Isolate Interface
VI-6777 LPCB Addressable Isolate Interface
FEATURES
- Voltage-type isolation module
- Loop power supply
- Easy Installation
- Dual isolate control
- Supports both Class A and Class B wiring modes
- LPCB approved to EN 54-17
TECHNICAL DATA
Operating Voltage 18-28V (Modulated-pulse)
Standby Current ≤1mA
Isolate Holding Current ≤10 mA
Action Condition Isolate input/output side short circuit or loop voltage ≤7.5V
Temperature Range -10°C ~ 50°C
Humidity ≤95%RH, (40±2°C) No condensation
Isolate Indication Active A or Active B LED Emitting
IP Rating IP32
Installation Base VB-6618
LPCB Conventional Fire and alarm system
VC-6831 LPCB Conventional Fire Alarm Control Panel
VC-6831 LPCB Conventional Fire Alarm Control Panel
DESCRIPTIONS
- High quality and reliable performance
- 2/4/8/16 detection zone
- Up to 25 devices for each zone
- Up to 4 programmable supervised sounder circuits
- LED indication and key buttons
- One man walk-test and zone isolate facility
- DAY/NIGHT mode switchable
- Fault buzzer mute facility
- Fully programmable using simple menu options
- Keypad entry to a wide range of functions
- Optional signal output board available for extension
- Three access levels settable via a key switch
- SMT and Microprocessor controller design
- Two wire system to reduce cabling and installation
- Compatible with wide range of conventional devices
- LPCB approved to EN54-2 and EN54-4
KEY FEATURES
Power Supply AC220V/50Hz or AC110V/60Hz
Operating Voltage 15VDC~28VDC
Sounder Circuit DC18V~28V, 300mA
Auxiliary Power DC18V~28V, 500mA
Temperature Range 0ᴼC~40ᴼC
Humidity ≤95%RH, (40±2ᴼC) No condensation
Battery Two DC12V/7Ah
Installation Wall-mount
Dimension 430*330*105mm
VC-6623 LPCB Conventional Smoke Detector
VC-6623 LPCB Conventional Smoke Detector
FEATURES
- 360ᴼ visible LED
- High performance on slow-burning or smoldering fire
- Build-in program of Drift compensation
- Intelligent algorithm and judgement
- Special chamber against interference
- Remote Indication Output
- Magnetic test available
- LPCB approved to EN54-7
TECHNICAL DATA
Operating Voltage 9DVC~28DVC
Quiescent Current ≤60µA
Alarm Current 10mA≤/≤50mA
Wiring Polarized two-wire
Temperature Range -10ᴼC~+55ᴼC
Humidity ≤95%RH, (40±2ᴼC) No condensation
Alarm Indicator Red Flashes periodically (2s – 4s) normally; lights steadily in alarm
Max Ripple Voltage 2V(peak-peak value)
Alarm Reset Instant power cut (2s Min, 1.0VDC Max)
IP Rating IP32
Installation Base VB6611
VC-6633 LPCB Conventional Heat Detector
VC-6633 LPCB Conventional Heat Detector
FEATURES
- 360ᴼ visible LED
- Thermal sensor with high sensitivity
- Classification of A2R
- Principle of Fixed Temperature and Rate of Rise
- Remote Indication Output
- Talented plug-in structure without screw
- Magnetic test available
- LPCB approved to EN54-5
TECHNICAL DATA
Operating Voltage 9DVC~28DVC
Static Current ≤60µA
Alarm Current 10mA≤/≤50mA
Wiring Polarized two-wire
Temperature Range -10ᴼC~+55ᴼC
Humidity ≤95%RH, (40±2ᴼC) No condensation
Fire LED Red Flashes once every 2s-4s in normal state; Illuminates in alarm
Max Ripple Voltage 2V (peak-peak value)
Alarm Reset Instant power cut (2s Min, 1.0VDC Max)
IP Rating IP32
Installation Base VB-6611
VC-6653 LPCB Conventional Manual Call point
VC-6653 LPCB Conventional Manual Call point
FEATURES
- Non-breaking and Resettable
- Flush-mount or Wall-mount
- Pluh-in structure and easy installation
- Stylish appearance
- Used in conventional line only
- Indoor use
- LPCB approved to EN 54-11
TECHNICAL DATA
Operating Voltage 24VDC (12VDC~28VDC)
Standby Current ≤0.5mA
Alarm Current ≤20mA (equivalent resistance is 470Ὠ/1W)
Wiring Two-wire
Temperature Range -10ᴼC~55ᴼC
Humidity ≤95%RH, (40±2ᴼC) No condensation
Indicator Red Illuminates after alarming
IP Rating IP43
VC-6734 LPCB Conventional Sounder Strobe
VC-6734 LPCB Conventional Sounder Strobe
FEATURES
- Audial and visual warning
- 16 tones available
- No external power supply required
- Fast responding time and low power consumption
- Plug-in structure and easy installation
- Used in conventional sounder circuit only
- LPCB approved to EN 54-3
TECHNICAL DATA
Operating Voltage Power 24V (21V-28V)
Operating Current Action Current ≤50mA
Flashing Frequency 1.4x(1±20%)Hz
Temperature Range -10ᴼC~50ᴼC
Humidity ≤955RH, (40±2ᴼC) No condensation
IP Rating IP21C
Static Current ≤60µA
Alarm Current 10mA≤/≤50mA
Wiring Polarized two-wire
Temperature Range -10ᴼC~+55ᴼC
Humidity ≤95%RH, (40±2ᴼC) No condensation
Fire LED Red Flashes once every 2s-4s in normal state; Illuminates in alarm
Max Ripple Voltage 2V (peak-peak value)
Alarm Reset Instant power cut (2s Min, 1.0VDC Max)
IP Rating IP32
Installation Base VB-6611
UL Exit and Emergency Light
TYI-P1000A UL Controller Operation Manual
TYI-P1000A UL Controller Operation Manual
FEATURES
- Compliant with UL 924 for Emergency Lighting and Power Equipment.
- State of the Art Touch Screen with 10-inch-wide display.
- Each Panel can support up to 2040 luminaires.
- 16320 luminaires on single Network
- With Multiple communication bridge 8Km distance can be achieved
- Central Monitoring Via Graphic application
- Panel on single Network
- Connectivity with BMS or Fire Alarm system
- Two levels of user access
TECHNICAL DATA
Rated Operating Voltage AC100-277V
Rated Operating Frequency 50/60Hz
Input Power 8W
Emergency Power 5W
Operating Environment Damp Location
Ambient Temperature Range for
Product Application 0ᴼC ~ 45ᴼC
Application Standard UL 924
Battery Type LiFePo₄Lithium-ion Battery
Battery Model IFR21700-6000
Battery Specification 3.2V, 6000mAh
Charging Time 24 hours
Minimum Initial Continuous
Emergency Operating Time 90 minutes
Mounting Methon Wall Mounted
TYI-CB1000A UL Communication Interface Bridge Module
TYI-CB1000A UL Communication Interface Bridge Module
FEATURES
- 255 Luminaire connected
- Easy Installation available
- Can be connect with all kinds of luminaire
- Meets UL certification standards
TECHNICAL DATA
Rated Operating Voltage AC100-277V
Rated Operating Frequency 50/60Hz
Input Power 35W
Emergency Power 6W
Operating Environment Damp Location
Ambient Temperature Range for
Product Application 0ᴼC ~ 45ᴼC
Application Standard UL 924
Battery Type LiFePo₄Lithium-ion Battery
Battery Model IFR21700-3000
Battery Specification 9.6V, 3000mAh
Battery Capacity 3000mAh
Charging Time 24 hours
Minimum Initial Continuous
Emergency Operating Time 90 minutes
TYI-EX-SH200A UL Evacuation Sign Light
TYI-EX-SH200A UL Evacuation Sign Light
FEATURES
- Lithium Iron Phosphate (LiFeP04)
- Universal Mounting Available
- 3 Hours Emergency Duration
- RAL9003
TECHNICAL DATA
Rated Operating Voltage AC100-277V
Rated Operating Frequency 50/60Hz
Input Power 5W
Emergency Power 0.5W
Operating Environment Damp Location
Ambient Temperature Range for
Product Application 0ᴼC ~ 45ᴼC
Application Standard UL 924
Battery Type LiFePo₄Lithium-ion Battery
Battery Model IFR1865-2000
Battery Specification 3.2V, 2000mAh
Charging Time 24 hours
Minimum Initial Continuous
Emergency Operating Time 180 minutes
Light Source Type LED
TYI-FM-SRC300A UL Lighting Luminaire
TYI-FM-SRC300A UL Lighting Luminaire
FEATURES
- Compliant with UL 924 for Emergency Lighting and Power Equipment
- High Performance LED
- Long life LEDs with 50,000hours (In Maintained Model)
- Lithium Iron Phosphate LiFeP04)
- Up to 2000 battery charging cycles
- Surface and Recessed Mounting
- RAL9003
TECHNICAL DATA
Rated Operating Voltage AC100-277V
Rated Operating Frequency 50/60Hz
Input Power 9W
Emergency Power 8W
Operating Environment Damp Location
Ambient Temperature Range for
Product Application 0ᴼC ~ 45ᴼC
Application Standard UL 924
Battery Type LiFePo₄Lithium-ion Battery
Battery Model IFR21700-3000
Battery Specification 9.6V, 3000mAh
Battery Capacity 3000mAh
Charging Time 24 hours
Minimum Initial Continuous
Emergency Operating Time 180 minutes
Mounting Height 4.5 meters
TYI-SR200A UL Surface Mount Exit Light
TYI-SR200A UL Surface Mount Exit Light
FEATURES
- Compliant with UL 924 for Emergency Lighting and Power Equipment
- High Performance LED
- Longlife LEDs with 50,000hours
- Lithium Iron Phosphate (LiFeP04)
- Up to 2000 battery charging cycle
- 4 Years battery design life
- Wall & Wall-Recessed Mounting
- Auto Tet
TECHNICAL DATA
Rated Operating Voltage AC100-277V
Rated Operating Frequency 50/60Hz
Input Power 9W
Emergency Power 8W
Operating Environment Damp Location
Ambient Temperature Range for
Product Application 0ᴼC ~ 45ᴼC
Application Standard UL 924
Battery Type LiFePo₄Lithium-ion Battery
Battery Model IFR21700-3000
Battery Specification 9.6V, 3000mAh
Battery Capacity 3000mAh
Charging Time 24 hours
Minimum Initial Continuous
Emergency Operating Time 180 minutes
Mounting Height 4.5 meters
FM Fire Fighting System
Horizontal End Suction Fire Pump Set
Horizontal End Suction Fire Pump Set
FEATURES
For UL/ FM project (Pump, Diesel Engine, Electrical motor, Controller, Main relief valve, Pressure meter, Flow meter are all listed)
TECHNICAL DATA
Pump Capacity: 100 GPM to 8000 GPM
Pump Pressures: 40 PSI to 362 PSI
Skids Fire Pump Set
Skids Fire Pump Set
DESCRIPTION
For UL/ FM project (Pump, Diesel Engine, Electrical motor, Controller, Main relief valve, Pressure meter, Flow meter are all Listed)
KEY FEATURES
- The exterior design is simple and aesthetically pleasing, with a rational layout of piping.
- Compliant with NFPA 20 standards, with all relevant components certified by FM/UL;
- Factory assembly
- The prying system undergoes factory testing to ensure outstanding performance.
- Significantly reduce on-site installation time for the users, accelerating the construction process.
Vertical Shaft Turbine Fire Pump Set
Vertical Shaft Turbine Fire Pump Set
DESCRIPTION
For UL/ FM project (Pump, Diesel Engine, Electrical motor, Controller, Main relief valve, Pressure meter, Flow meter are all listed)
KEY FEATURES
Building Passive Fire Protection System
Air Fireproof & Heat insulating Finished
Air Fireproof & Heat insulating Finished
FEATURES
THE CORAL® (Floating Bead) Fireproof & Heat insulating Finished Air Duct.
Self-supporting integrated structure, one-stop to meet fire insulation performance
Adopted EN 1366-1 certification
TECHNICAL DATA
Lightweight and high strength:
Volume density 600kg/m³. Anti-brittle strength 10 MPa
Fire and heat insulation:
Single panel fire resistance limit 4h. Thermal conductivity 0.16 W/ (m·K)
Stable and durable
Free chloride ion content <0.1%. Softening coefficient> 80%
Safety and non-combustibility
Class A1 non-combustible. Toxicity safety level AQ1
DOWNLOAD
System Catalogs & Product Brochures .
Download our comprehensive, high-resolution product catalogs for offline review, project submittals, or client presentations.
- GNC Full-Line Fire Protection Systems Overview
- Intelligent Fire Detection Catalog
- Commercial Alarm Systems Guide
- Architectural & Passive Fire Containment Solutions
TECHNICAL SUPPORT & INQUIRIES
Facing complex project specs?
Let’s resolve them.
Our global engineering team is ready to streamline your building fire safety compliance metrics. Whether you are cross-checking multi-brand system listings or navigating regional fire codes, we provide responsive, code-compliant solutions backed by our dedicated technical support specialists.
General Inquiry
- +86 769 8232 2001
- info@gncsafety.com
Technical Support
- +63 917 185 9190
- contact@gncsafety.com